{"product_id":"supervised-signal-isolator-module-csis-202a1","title":"Supervised Signal Isolator Module CSIS-202A1","description":"\u003cp\u003e[short_description]  Supervised signal isolator module with two supervised outputs for isolating compatible bells, horns, and strobes while maintaining fire alarm circuit integrity.[\/short_description] [product_description]\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"695\" data-end=\"919\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"699\" data-end=\"747\"\u003eCSIS-202A1 Supervised Signal Isolator Module\u003c\/strong\u003e is designed for fire alarm installations where an in-suite audible or visual notification device must be isolated without affecting notification appliances in other areas.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"921\" data-end=\"1307\"\u003eThe module provides \u003cstrong data-start=\"941\" data-end=\"976\"\u003etwo supervised isolator outputs\u003c\/strong\u003e. If a connected bell, horn, or strobe develops a short or open circuit, the isolator removes the affected devices from the circuit while allowing the remaining notification appliances to continue operating. The fire alarm control panel can indicate a trouble condition for the affected suite. \u003cspan class=\"contents\" data-content-reference-start=\"1248\" data-content-reference-end=\"1282\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1309\" data-end=\"1618\"\u003eThe CSIS-202A1 mounts in a standard \u003cstrong data-start=\"1345\" data-end=\"1377\"\u003e4-inch square electrical box\u003c\/strong\u003e and includes a white front plate with an area for identifying the suite number. It operates from a regulated \u003cstrong data-start=\"1487\" data-end=\"1504\"\u003e24 FWR\/24 VDC\u003c\/strong\u003e signal input and supports up to \u003cstrong data-start=\"1537\" data-end=\"1579\"\u003e400 mA maximum suite current per suite\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"1556\" data-content-reference-end=\"1576\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1620\" data-end=\"1637\"\u003e\u003cstrong data-start=\"1620\" data-end=\"1637\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1638\" data-end=\"2089\"\u003e\n\u003cli data-start=\"1638\" data-end=\"1671\"\u003eTwo supervised isolator outputs\u003c\/li\u003e\n\u003cli data-start=\"1672\" data-end=\"1703\"\u003eOperates with bells and horns\u003c\/li\u003e\n\u003cli data-start=\"1704\" data-end=\"1763\"\u003eCompatible with notification appliances including strobes\u003c\/li\u003e\n\u003cli data-start=\"1764\" data-end=\"1811\"\u003eHelps maintain notification circuit integrity\u003c\/li\u003e\n\u003cli data-start=\"1812\" data-end=\"1872\"\u003eIdentifies short\/open conditions on isolated suite signals\u003c\/li\u003e\n\u003cli data-start=\"1873\" data-end=\"1901\"\u003e24 FWR\/24 VDC signal input\u003c\/li\u003e\n\u003cli data-start=\"1902\" data-end=\"1932\"\u003e400 mA maximum suite current\u003c\/li\u003e\n\u003cli data-start=\"1933\" data-end=\"1984\"\u003eMounts in a standard 4-inch square electrical box\u003c\/li\u003e\n\u003cli data-start=\"1985\" data-end=\"2004\"\u003eWhite front plate\u003c\/li\u003e\n\u003cli data-start=\"2005\" data-end=\"2089\"\u003eULC listed according to Mircom documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e    [\/product_description]\u003c\/p\u003e","brand":"Mircom","offers":[{"title":"Default Title","offer_id":43756185681981,"sku":"MIR-NAC-CSIS202A1","price":160.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0668\/9924\/7165\/files\/images_31.jpg?v=1791027045","url":"https:\/\/myfireshop.ca\/products\/supervised-signal-isolator-module-csis-202a1","provider":"MyFire Shop","version":"1.0","type":"link"}